Water Leaks

Check top tub gasket (Page 5-3).

Check water inlet hoses at machine and

iauceX(Page 1-5).

Check drain hose clamps at pump and
drain inlet.

Check tub to pump hose clamp.

Check pump for cracks or seal damage
(Page 5-5).

Check water mixing valve for cracks or
hose connection leak.

• Check center seal for leak (Page 7-2).

Check for water inlet flume damage

(Page 5-2).

Fills - Will Not Agitate

IF MOTOR RUNS:

• Check for broken belt.

• Check for pivot spring in place.

• Check for motor mount glides in place.

• Check for problem with transmission

(Page 7-12).

Check drive pulley movement (Page 7-4).

Turning pulley clockwise should oscil­

late the agitator and turning counter­
clockwise will release the brake for spin­
ning action. If pulley does not turn, replace
transmission.

If pulley and transmission are operating

correctly, check for obstruction in pump

(Page 5-5).

• If motor does not run:

Check pressure switch contacts (Page 8-

16).

Check timer contacts (Page 8-3).

Check selector switch (Page 8-17).

- Check motor start switch (Page 8-12).

Check motor winding and thermal over

load (Page 8-11 and 8-12).

Excessive Noise - Vibration

Check for proper installation.

Legs level and secure (Page 1-3).

Stabilizer rear legs secure (Page 4-11).

Sound and secure flooring (Page 4-11).

Check motor pulley and bearings

(Page 8-15).

Check pump pulley and bearing
(Page 5-5).

Check belt.

Check transmission pulley for correct

thrust bearing adjustment (Page 7-6).

Check transmission for spin bearing noise.

Check center tub seal (Page 7-2).

Check agitator for correct installation.

Remove front panel and check that the six
suspension springs are attached to the
base and outer tub (Page 6-2).

16009485-01

©1999 Maytag Appliances Sales Company

Section 9. Troubleshooting

9-3