Will Not Fill/Slow Fill
(MAV5000, MAV5057)
Check that water faucets are on.
Check for blockage in screens.
Check for kinked inlet hoses.
Is washer plugged into power supply?
Is 120VAC present at outlet (Page 1-2)1
Check for blown fuse or tripped breaker.
Pull out timer knob.
Push water temperature selector button
(Page 8-17).
Check lid switch assembly (Page 8-19).
Check Pressure Switch for continuity be
tween terminals (Page 8-16 or for loose/
damaged wires.
Check timer contacts (Page 8-3).
Check for continuity on water valve
solenoid(s) (Page 8-10).
Will Not Fill/Slow Fill
{MAV6000, MAV6057, MAV7000, MAV7057,
MAV8000 & MAV8057)
• Check all symptoms listed under Model
MAV5000.
• Check wires at АТС board for good termi
nal connections (Page 8-4).
• Check for damaged components on АТС
board.
Water Temperature Incorrect
•
With the tub empty, place machine in nor
mal wash and pull timer knob out.
•
Deselect АТС (if available).
•
Fully press Hot/Cold Temp setting. Hot
water should flow.
•
Fully press Warm/Cold setting. Warm
water should flow.
•
Fully press Cold/Cold setting. Cold water
should flow.
•
If temperatures are not correct, check for
reversed inlet hoses at faucets or at water
valve. Or, check for inappropriate wiring
of water valve harness, wires reversed in
timer connector (Page 8-3), wires reversed
at АТС (Page 8-4), bad thermistor in water
valve (Page 8-10), and inappropriate wir
ing of temperature switch (Page 8-19).
Overfills
•
Check water pressure to machine. If less
than 4 PSl, it is normal for water to flow
through valve. Increase water pressure.
•
If water pressure is adequate, disconnect
power cord from outlet. Does water con
tinue to flow? If yes, replace water valve
(Page 5-1).
•
Check water level pressure switch for
proper operation (Page 8-16).
• Examine air dome hose for leaks
(Page 4-1 and 5-5).
•
Check for obstruction blocking air dome
hoses (Page 4-5 and 5-5),
16009485-01