Disassembly and testing, Centrifugal switch, Overload – Maytag Atlantis User Manual
Page 116: Water valves, Cold, Main winding, Start winding
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Section 1. Product Definition;
The Atlantis III is similar to previous Atlantis washer models, with the following exceptions:
•
The Control Wire Harness has a connector
• A new non-serviceable water pump,
which allows removal of the entire Console
Assembly from the cabinet.
•
Automatic Temperature Control. The incoming
water temperature is controlled by 2 thermostats
attached to the Injector Assembly.
Section 2. Console
Disassembly and Testing
The Console Assembly has been designed to allow full
removal of the console from the cabinet via a plug
added to the wiring harness. This feature will also aid
in performing diagnostic tests to the various
Centrifugal Switch
Attach Ohm Meter leads to BK 32 and OR 31 .5 ohms.
Overload
Attach Ohm Meter leads to WH 9 and YL M .5 ohms.
Water Valves
Hot
Attach Ohm Meter leads to OR 13 and BR151 ohm.
Cold
Atteich Ohm Meter leads to BU 11 and BR 1 ohm.
Main Winding
Attach Ohm Meter leads to WH 9 and BK 32 2 ohms.
Start Winding
16009485-03 Rev. 0
©2002 Maytag Appliances Company