Maytag Atlantis User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Setting
Gallons
*Depth
Inches
*Basket
Perforations
Mini
10.5
6"
3 1/2“
Medium
14.1
8 1/2“
5“
High
19.5
11"
7“
Super
23.3
13 1/2“
9 1/4"
^Allowable variations are plus or minus 1/2 inch.
AGITATOR SPEED
Regular Cycle
88 Oscillations per minute
155 Degree Arc
Slow (Delicate) Cycle
57 Oscillations per minute
155 Degree Arc
SPIN SPEED
Regular Cycle
620 R.RM.
Slow (Fine Wash) Cycle
410 R.RM.
TABLE 1-1. AMPERAGE CHART
CYCLE
WATER
LEVEL
♦AMPS
Agitate-Regular
Full Tub
10.4
Agitate-Slow
Full Tub
7.6
Agitate-Regular
DryTub
7.5
Spin-Regular
DryTub
10.2
Spin-Slow
DryTub
7.6
Pump Out-Regular
Full Tub
10.8
Pump Out-Slow
Full Tub
8.0
TABLE 1-2. RESISTANCE CHART
COMPONENTS
♦RESISTANCE
(OHMS)
Timer Motor
2360
Mixing Valve
500-1000
Cold Solenoid
853
/Vof Solenoid
867
Drive Motor
High Speed
1.3
Low Speed
2.3
Start
3.1
* These values can vary slightly.
TABLE 1-3. WATTAGE CHART
CYCLE
♦WATTAGE
RANGE
Agitate-Regular
Full Tub
610-640/670 (MAX.)
Agitate-Slow
Full Tub
370-400/420 (MAX.)
Agitate-Regular
DryTub
460^70/480 (MAX.)
Agitate-Slow
DryTub
350-360/370 (MAX.)
Pump Out-Regular
760
Pump Out-Slow
510
Spin-Regular
Full Tub
460
Spin-Slow
Full Tub
340
* These will vary with washer load and line voltage.
16009485-01
©1999 Maytag Appliances Sales Company
Section 1. General Information
1-8