SECTION 1. GENERAL INFORMATION
WASHER PRE-IIMSTALLATION
REQUIREMENTS
NOTE: Proper installation is the responsi
bility of the purchaser.
Checkpoints for proper installation:
•
Properly grounded electrical outlet is
required. Use 15 amp fuse or compa
rable circuit breaker for electrical
service.
•
Standpipe Drain System must be able to
accept IVa" O.D. drain hose. In cases
where an air tight connection is re
quired, an anti-siphoning valve, part
number 12001586, should be placed in
the drain hose to prevent siphoning
from the washer or facility during
agitation. Standpipe height of 36" is
recommended.
NOTE: if drain standpipe is in excess of
5 feet above floor level, install pump
accessory kit, part number 12001587.
•
These units are not equipped with a
siphon break, and the drain hose must
be elevated to a minimum height of 36".
For installations with short standpipes,
the drain hose must be supported by
clipping the drain hose into the clip on
the back of the washer. Then a coupler
and additional hose length is added to
the existing drain hose.
•
Hot and Cold water faucets should be
within four (4) feet of the back of the
washer. This allows for quick access for
immediate shut off of the water.
Do not store or operate washer in tem
peratures below freezing. This can cause
damage to the pump, hoses and other
components. (See page 1-5 for long term
storage.)
Water pressure of 20 -120 RS.I. is required
to fill the washer in the appropriate time
frame. Pressures of less than 20 RS.I. may
cause an extended or exceptionally long
fill time. Refer to the troubleshooting sec
tion for more information regarding a so
lution for slow fill situations.
Best performance is obtained with the
washer installed on a solid floor. Wood
floor constructions may need to be rein
forced to minimize vibration from unbal
anced load situations. Carpets and soft
tile surfaces are also contributing factors
in vibration and/or movement during the
spin cycle. Never install washer on plat
form or weak support structure.
ELECTRICAL REQUIREMENTS
1. Provide an individual 120 volt, 60 HZ,
branch circuit with ground for the washer.
This circuit must be rated for 15 amperes
or more.
2. Protect the washer's electrical circuit with
a 15 ampere time delay fuse or circuit
breaker.
3. Install in accordance with National
Electrical Code and all local codes
and ordinances.
W
Water heater should be set to deliver a
minimum of 120° (49°C) hot water to
the washer.
16009485-01
©1999 Maytag Appliances Sales Company
Section 1. General Information
1-1