Potter PFC-4410RC User Manual
Page 8

8
PFC-4410RC • 5403550 • REV Q • 11/12
· Signal Silence button
· Buzzer Silence button
· Manual event scroll buttons
· Automatic resound of silenced trouble signals after 24 hours
· Built-in Trouble buzzer
· Common Contacts for Alarm/Trouble/Supervisory/Waterflow
· 32 Character Liquid Crystal Display (LCD)
· 34 LED display
· User Generated Banner Message
· User Generated Zone Labeling
· 24 or 90 hour Battery Standby available (Where required by FM and Others)
· 24 Hour Clock
· Password Protection
· Remote annunciator output
· 4-Wire resettable smoke detector power
Options See Appendix B of the manual for product data sheets.
1. CAM - Module to convert one Class B Indicating Appliance Circuit to one Class A circuit.
2. CA2Z - Module to convert two Class B Initiating Device Circuits to two Class A circuits.
3. ARM-1 - Module to provide non-supervised 4PDT Relay designed to be activated by 24VDC Indicating and/or Releasing,
polarity reversing circuits.
4. ARM-2 - Module to provide two Form C contacts activated by Indicating or Releasing, polarity reversing circuits.
5. ARM-44 - Module to provide 8 Form C contacts activated by corresponding initiating zones and outputs. Contact
manufacture for data sheet 5401202.
6. RA-4410RC – Remote annunciator provides 34 LED’s for each zone in alarm supervisory or trouble, each output activated
or in trouble, AC power, Power trouble, System trouble, Ground fault, Supervisory, Supervisory trouble, Alarm, Alarm
silence and Pre-discharge/Discharging. The annunciator also has a lamp test switch. Contact manufacture for data sheet
5401175.
7. Abort switch. Contact manufacture for data sheet 5401136.
8. RCDS-1 - Releasing Circuit Disable Switch Contact manufacture for data sheet 5401214.
Ordering Information
Model No.
Description
Stock No.
RA-4410RC
Remote annunciator
3006400
BB-RA-44R
Surface mount back box for RA-4410RC
3006401
EOLP-R
End of Line Plate f/Resistor
3002182
EOLP-D
End of Line Plate f/Diode Assy
3002181
P32-1T
Manual release station
1000447
Abort Switch
3001000
PFC-TW
Bezel for semi-flush mounting (white)
5090157
PFC-TR
Bezel for semi-flush mounting (red)
5090155
BT80
Battery, for 24 hour standby, 12V, 8.0AH (2 req’d)
5130084
BT120
Battery, for 60-90 hour standby, 12V, 12.0AH (2 req’d)
5130090
CA2Z
2-Zone Class A initiating module
3006013
CAM
Class A indicating circuit module
3005300
ARM-1
Auxiliary Relay Module 4 Pole
3004726
ARM-2
Auxiliary Relay Module
3004725
ARM-44
8 Relay Module
3006221
RCDS-1
Releasing Circuit Disable Switch
3001002
Spare or Replacement Parts
EOL Resistor
5080593
EOL Resistor and Diode Assembly for releasing circuit
3005012
EOL Resistor with 6" wire leads
3005013
eMatch Protection Assembly for eAEROSOL circuit
3005014
Main Circuit Board Module
3006230
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference
to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules which
are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area
is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.