Minimum boiler

water level ALARM

minimum boiler water level alarm

solutions:

-

check boiler input; see parameter t27

main consequences:

-

the boiler temperature regulation output will be deactivated

Maximum boiler

water level ALARM

cooking fumes probe alarm

solutions:

-

check boiler input; see parameter t28

main consequences:

-

the boiler temperature regulation output will be deactivated

Boiler drain

ALARM

boiler drain alarm

solutions:

-

check Min, Max H2O Boiler inputs; see parameter t21

main consequences:

-

the boiler temperature regulation output will be deactivated

Boiler

communication

ALARM

control module-boiler expansion module communication alarm

solutions:

-

check the control module-boiler expansion module connection

main consequences:

-

all boiler regulation outputs will be deactivated

ALLARME

sicurezza boiler

boiler safety alarm

solutions:

-

check the reasons that caused the input activation

main consequences:

-

all boiler regulation outputs will be deactivated

Room/boiler

burner fault

ALARM

room/boiler burner fault alarm

solutions:

-

check the reasons that caused the burner fault

main consequences:

-

the room/boiler burner will be deactivated

Room burner

ALARM

Room/boiler burner alarm

solutions:

-

check the correct operation of the respective centrifugal fan, the hall sensor feedback signal and

parameters b5/b6 (room) or b12/b13 (boiler)

main consequences:

-

the room/boiler burner will be deactivated

When the problem that caused the error disappears, the device is restored to normal operation.