Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 52 of 66

u2

0

600

ds (s/10)

120

air vent output inhibition duration from the conclusion of the brief

impulse for air vent opening and from the conclusion of the long

impulse for air vent closure (only if u1 = 1); see also u3 and u4

u3

0

600

ds (s/10)

10

duration of the brief impulse for air vent opening (only if u1 = 1);

see also u2 and u4

u4

0

600

ds (s/10)

30

duration of the long impulse for air vent closure (only if

u1 = 1); see also u2 and u3

PARAM.

MIN.

MAX.

U.M.

DEF.

SERIAL NETWORK

LA

1

247

- - -

247

device address

Lb

0

3

- - -

2

baud rate

0

=

2.400 baud

1

=

4.800 baud

2

=

9.600 baud

3

=

19.200 baud

LP

0

2

- - -

2

parity

0

=

none (no parity)

1

=

odd

2

=

even

PARAM.

MIN.

MAX.

U.M.

DEF.

ROTOR

k0

0

1

- - -

0

enables rotor

k1

0

1

- - -

1

door action on rotor: the door opening stops the rotation When the

door is closed afterwards,

0

=

the motor remains still

1

=

it restarts as before the interruption

k2

0

100

s

10

maximum motor activation duration. k2=0 immediately stops the

motor when opening the door.

k3

0

1

- - -

0

type of rack limit switch input contact

0

=

normally open (input active with closed contact)

1

=

normally closed (input active with open contact)

PARAM.

MIN.

MAX.

U.M.

DEF.

CLEANING

w0

0

500

°C/°F (2)

60

working set point for the precleaning phase