EVCO S.p.A.

Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 57 of 66

No connection

ALARM

user interface-control module communication alarm

solutions:

-

check user interface-control module connection

main consequences:

-

if the alarm occurs when the device is on, a cooking cycle cannot be started

-

if the alarm occurs during a cooking cycle, no consequence

Temperature

ALARM

maximum temperature alarm

solutions:

-

check the temperature detected by the environment probe; see parameters A0, A1 and A3

main consequences:

-

no consequence

Board

temperature

alarm

ALARM

use temperature alarm.

solutions:

-

check the use temperature of the control module; see parameter A4

main consequences:

-

if the alarm occurs when the device is on, a cooking cycle cannot be started

-

if the alarm occurs during a cooking cycle, the cycle will be interrupted

-

the air vent will be opened, the technical compartment fan will be switched on and the remaining

outputs will be switched off.

door micro switch input alarm

solutions:

-

check the causes of the input activation; see parameter i0

main consequences:

-

if the alarm occurs during a cooking cycle, the temperature regulation output, the fan and the

steam injection output will be switched off and the vent will be opened

Circuit breaker

protection ALARM

fan circuit breaker protection input alarm

solutions:

-

check the causes of the input activation; see parameters i1 and i2

main consequences:

-

if the alarm occurs during a cooking cycle, the temperature regulation output and the fan will be

switched off

Peak absor.

ALARM

electric absorption input alarm

solutions:

-

check the causes of the input activation; see parameter i4

main consequences:

-

if the alarm occurs during a cooking cycle, the outputs will be switched off

Boiler probe

ALARM

boiler probe alarm

solutions:

-

check the probe type; see parameter P0

-

check the device-probe connection

-

check the boiler temperature

main consequences:

-

the boiler temperature regulation output will be deactivated