EVCO EVCLC33DJ2 User Manual
Page 50

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 50 of 66
t12
0
500
°C/°F (2)
120
temperature above which the injection of steam generated in direct
mode is activated and below which the injection of steam generated
with external humidifier is activated (referring to the temperature
detected by the environment probe; only if t0 = 2)
t13
0
500
°C/°F (2)
90
temperature above which cooking fumes reduction is activated
(referring to the temperature detected by the fumes probe); see
also t14
t14
1
99
°C/°F (2)
5
differential of t13
t15
0
1
---
0
enabling the Boiler expansion
1
= YES
t16
1
500
°C/°F (2)
80
boiler temperature above which the injection of boiler steam is
enabled
t17
1
500
°C/°F (2)
95
boiler steam working temperature
t18
1
500
°C/°F (2)
70
boiler steam holding temperature
t19
1
99
°C/°F (2)
2
hysteresis for t17, t18
t20
0
240
s
2
time delay for boiler water charge
t21
0
240
min
2
time delay for boiler water drain
t22
0
240
min
25
descaler action time for Cleaning phase 1
t23
1
500
°C/°F (2)
60
descaler action temperature for Cleaning phase 1
t24
0
240
min
20
cleaning action time for phase 2
t25
1
500
°C/°F (2)
60
cleaning action temperature for phase 2
t26
1
10
---
3
number of cleaning cycles phase 2
t27
0
240
s
5
minimum water level alarm delay
t28
0
240
min
3
maximum water level alarm delay
PARAM.
MIN.
MAX.
U.M.
DEF.
TEMPERATURE ALARMS
A0
1
99
°C/°F (2)
10
differential of A1