Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 50 of 66

t12

0

500

°C/°F (2)

120

temperature above which the injection of steam generated in direct

mode is activated and below which the injection of steam generated

with external humidifier is activated (referring to the temperature

detected by the environment probe; only if t0 = 2)

t13

0

500

°C/°F (2)

90

temperature above which cooking fumes reduction is activated

(referring to the temperature detected by the fumes probe); see

also t14

t14

1

99

°C/°F (2)

5

differential of t13

t15

0

1

---

0

enabling the Boiler expansion

1

= YES

t16

1

500

°C/°F (2)

80

boiler temperature above which the injection of boiler steam is

enabled

t17

1

500

°C/°F (2)

95

boiler steam working temperature

t18

1

500

°C/°F (2)

70

boiler steam holding temperature

t19

1

99

°C/°F (2)

2

hysteresis for t17, t18

t20

0

240

s

2

time delay for boiler water charge

t21

0

240

min

2

time delay for boiler water drain

t22

0

240

min

25

descaler action time for Cleaning phase 1

t23

1

500

°C/°F (2)

60

descaler action temperature for Cleaning phase 1

t24

0

240

min

20

cleaning action time for phase 2

t25

1

500

°C/°F (2)

60

cleaning action temperature for phase 2

t26

1

10

---

3

number of cleaning cycles phase 2

t27

0

240

s

5

minimum water level alarm delay

t28

0

240

min

3

maximum water level alarm delay

PARAM.

MIN.

MAX.

U.M.

DEF.

TEMPERATURE ALARMS

A0

1

99

°C/°F (2)

10

differential of A1