EVCO EVCLC33DJ2 User Manual
Page 47

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 47 of 66
r7
0
r8
°C/°F (2)
0
minimum delta T set-point (referring to the temperature detected by
the needle probe)
r8
r7
150
°C/°F (2)
30
maximum delta T set-point (referring to the temperature detected
by the needle probe)
r9
r7
r8
°C/°F (2)
5
delta T set-point for factory setting (referring to the temperature
detected by the needle probe)
r10
-199
199
°C/°F (2)
10
work set-point during preheat (relative to the work set-point during
the first phase of the cooking cycle, i.e. “work set-point during the
first phase of the cooking cycle + r10”; referring to the temperature
detected by the environment probe); see also parameter r0
r11
0
500
°C/°F (2)
50
work set-point during cooling (referring to the temperature detected
by the environment probe)
r12
0
240
min
240
duration of a power supply cut-off (3), occurring during a cooking
cycle, that may cause interruption
PARAM.
MIN.
MAX.
U.M.
DEF.
VARIOUS
c0
-1
120
s
10
duration of buzzer activation on conclusion of the cooking cycle
-1
=
until it is silenced by hand
c1
0
1
- - -
0
activation of the buzzer (for 1 s) on conclusion of a cooking cycle
phase
c2
0
240
min
60
time that must elapse without operations on the device (from
activation of the “Weekly programmed switch-on”) until this
switches off
c3
0
99
°C/°F (2)
10
temperature above which the display of the temperature detected by
the environment probe is locked (relative to the work set-point, i.e.
“work set-point + c3”)
0
=
function absent
c4
0
99
°C/°F (2)
10
temperature above which the display of the temperature detected by
the environment probe is locked (relative to the work set-point, i.e.
“work set-point - c4”)
0
=
function absent