EVCO EVCLC33DJ2 User Manual
Page 56

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 56 of 66
18
ALARMS
18.1
Alarms
A buzzer is activated if an alarm occurs, the display shows the icon
and an alarm code. Touch the display in the centre to silence the
buzzer and restore normal display.
The following table illustrates the meaning of the device alarm codes.
ALARM CODE
MEANING
Chamber probe
ALARM
chamber probe alarm
solutions:
-
check the type of probe; see parameter P0
-
check the device-probe connection
-
check the temperature of the chamber
main consequences:
-
if the alarm occurs when the device is on, a cooking cycle cannot be started
-
if the alarm occurs during a cooking cycle, the cycle will be interrupted
-
the output for temperature regulation will be switched-off
Core probe
ALARM
core probe alarm
solutions:
-
the same as the preceding case but with respect to the core probe
main consequences:
-
if the alarm occurs when the device is on, a Delta T and a core cooking cycle cannot be allowed
-
if the alarm occurs during a Delta T or core cooking cycle, the cycle will be interrupted
Cooking fumes
probe offset
alarm
cooking fumes probe alarm
solutions:
-
the same as the preceding case but with respect to the fumes probe
main consequences:
-
the output for management of fumes reduction will be switched off
No voltage
ALARM
power supply cut-off alarm
solutions:
-
check the device-power supply connection
main consequences:
-
if the alarm occurs when the device is on or off, once the power supply is restored, the device
will be switched off.
-
if the alarm occurs during the cooking cycle and the duration of said interruption is lower than
the time established with parameter r12, when the power supply is restored, the cycle will be re-
proposed from the start of the phase during which the power cut occurred (if vice versa the
duration of the interruption is longer than the time established with parameter r12, when the
power supply is restored, the cycle will be interrupted).