beautypg.com

EVCO EVCLC33DJ2 User Manual

Page 56

background image

EVCO S.p.A.

Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 56 of 66

18

ALARMS

18.1

Alarms

A buzzer is activated if an alarm occurs, the display shows the icon

and an alarm code. Touch the display in the centre to silence the

buzzer and restore normal display.

The following table illustrates the meaning of the device alarm codes.

ALARM CODE

MEANING

Chamber probe

ALARM

chamber probe alarm

solutions:

-

check the type of probe; see parameter P0

-

check the device-probe connection

-

check the temperature of the chamber

main consequences:

-

if the alarm occurs when the device is on, a cooking cycle cannot be started

-

if the alarm occurs during a cooking cycle, the cycle will be interrupted

-

the output for temperature regulation will be switched-off

Core probe

ALARM

core probe alarm

solutions:

-

the same as the preceding case but with respect to the core probe

main consequences:

-

if the alarm occurs when the device is on, a Delta T and a core cooking cycle cannot be allowed

-

if the alarm occurs during a Delta T or core cooking cycle, the cycle will be interrupted

Cooking fumes

probe offset

alarm

cooking fumes probe alarm

solutions:

-

the same as the preceding case but with respect to the fumes probe

main consequences:

-

the output for management of fumes reduction will be switched off

No voltage

ALARM

power supply cut-off alarm

solutions:

-

check the device-power supply connection

main consequences:

-

if the alarm occurs when the device is on or off, once the power supply is restored, the device

will be switched off.

-

if the alarm occurs during the cooking cycle and the duration of said interruption is lower than

the time established with parameter r12, when the power supply is restored, the cycle will be re-

proposed from the start of the phase during which the power cut occurred (if vice versa the

duration of the interruption is longer than the time established with parameter r12, when the

power supply is restored, the cycle will be interrupted).

This manual is related to the following products: