EVCO EVCLC33DJ2 User Manual
Page 28

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 28 of 66
8
COOKING CYCLE
8.1
Preliminary notes
Every cooking cycle is preceded by preheating (on condition
that Delta T cooking has not been set; the work set-point is
relative to the work set-point during the first phase of the
cooking cycle, i.e. "work set-point during the first phase of the
cooking cycle + work set-point during preheating").
During pre-heat, the fan is switched-on at maximum speed.
When the temperature detected by the environment probe
reaches the work set-point, the buzzer is activated for 3 s.
The opening and closing of the door causes the passage to the
first phase of the cooking cycle.
Every cooking cycle is made up from a minimum of one to a
maximum of six phases; on conclusion of a phase, the device
moves automatically to the next.
For every phase, the device can manage the following
settings:
-
the type of cooking:
-
timed (the phase has duration for the time set and
the work set-point is an absolute value)
-
with Delta T (only if the needle probe is enabled,
i.e. if parameter P2 is set at 1; the phase has
duration until the temperature detected by the
needle probe reaches the core set-point and the
work set-point is a delta referred to the
temperature detected by the needle probe, i.e.
“temperature detected by the needle probe +
Delta T set-point)
-
core (only if the needle probe is enabled, i.e. if the
parameter P2 is set at 1; the phase has duration
until the temperature detected by the needle
probe reaches the core set-point and the work set-
point is an absolute value)
-
the work set-point (only if timed or core cooking
has been set)
-
the Delta T set-point (only if Delta T cooking has
been set)
-
the humidification
-
the duration of the phase (only if timed cooking
has been set)
-
the core set-point (only if Delta T or core cooking
has been set)
-
the fan speed (only if fan management has been
set in “on/off” mode with dual speed or in
modulating mode, i.e. if the parameter F0 is set at
2 or 3)
-
anticipation time of the air vent automatic opening
before phase conclusion (only if timed cooking has
been set).