In the BOILER menu, it will be possible to select the function

Starting this cycle, the following phases will be performed

1.

Water charge to maximum level.

2.

Water drain.

3.

Water charge to maximum level.

4.

Water drain.

If the drain fails, the alarm “BOILER DRAIN”

If the maximum required level is not reached within the expected time

activated and it will be possible to reset it from

In the event of “BOILER DRAIN” or “MAX BOILER WATER LEV

To exit, press the

key; to stop the cycle during an alarm, keep pushed the

14.3.4

Boiler cleaning

It is possible to access the BOILER menu from the settings menu.

In the BOILER menu, it will be possible to select the function CLEANING

When pressing CLEANING, a password will be requested

Starting this cycle, the following phases will be performed:

1.

Water charge to maximum level.

2.

Water drain.

3.

Descaler charge request: the charge

4.

Water charge to maximum level.

5.

Descaler action activation: its duration depends on parameter

on parameter t23.

6.

Water drain.

7.

Water charge to maximum level.

8.

Cleaning action activation: its duration depends on parameter

on parameter t25.

9.

Next step is point 6. The cleaning

t26. The cleaning ends with the Boiler

Vcolor 338 L | Installer manual ver. 2

page 40 of 66

In the BOILER menu, it will be possible to select the function RINSE

the following phases will be performed:

will be activated and it will be possible to reset it from

If the maximum required level is not reached within the expected time (parameter t28), the alarm “MAX BOILER WATER LEV”

activated and it will be possible to reset it from

key.

MAX BOILER WATER LEV” alarms, the rinse will temporarily stop until the cause is removed.

to stop the cycle during an alarm, keep pushed the

key for 4 seconds.

It is possible to access the BOILER menu from the settings menu.

it will be possible to select the function CLEANING

will be requested (default “1”).

Starting this cycle, the following phases will be performed:

charge will be manually performed, to proceed press the

key.

its duration depends on parameter t22, while the water heating to a certain temperature depends

its duration depends on parameter t24, while the water heating to a certain temperature depends

phase (points 6,7,8) will be performed a certain number of times according to

Boiler water drain.

| Installer manual ver. 2.0 | Code 144VC338LE204

key.

the alarm “MAX BOILER WATER LEV” will be

temporarily stop until the cause is removed.

key for 4 seconds.

key.

while the water heating to a certain temperature depends

while the water heating to a certain temperature depends

be performed a certain number of times according to parameter

This manual is related to the following products: