EVCO S.p.A.

Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 54 of 66

PARAM.

MIN.

MAX.

U.M.

DEF.

BURNERS

b0

2500

6000

RPM

5000

room burner fan maximum RPM

b1

1500

4000

RPM

2500

room burner fan minimum RPM

b2

1000

3000

RPM

1000

room burner fan ignition RPM

b3

1

99

°C/°F (2)

10

proportional band for room temperature regulation

b4

2

10

sec

3

room burner fan ramp time

b5

200

1000

RPM

200

room burner fan RMP feedback alarm threshold

b6

10

120

sec

10

room burner fan RMP feedback alarm delay

b7

2500

6000

RPM

5000

boiler burner fan maximum RPM

b8

1500

4000

RPM

2500

boiler burner fan minimum RPM

b9

1000

3000

RPM

1000

boiler burner fan ignition RPM

b10

1

99

°C/°F (2)

10

proportional band for boiler temperature regulation

b11

2

10

sec

3

boiler ramp time

b12

200

1000

RPM

200

boiler burner fan RMP feedback alarm threshold

b13

10

120

sec

10

boiler burner fan RMP feedback alarm delay

b14

0

1

---

0

oven type 0 = electric, 1 = gas

Notes

(1)

Properly set the parameters corresponding to the regulators after setting parameter P1

(2)

the unit of measurement depends on P1

(3)

if the duration of the power cut is shorter than the time established with parameter r12, when the power supply is restored,

the cycle will be re-proposed from the start of the phase running during power cut.