EVCO EVCLC33DJ2 User Manual
Page 54

EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 54 of 66
PARAM.
MIN.
MAX.
U.M.
DEF.
BURNERS
b0
2500
6000
RPM
5000
room burner fan maximum RPM
b1
1500
4000
RPM
2500
room burner fan minimum RPM
b2
1000
3000
RPM
1000
room burner fan ignition RPM
b3
1
99
°C/°F (2)
10
proportional band for room temperature regulation
b4
2
10
sec
3
room burner fan ramp time
b5
200
1000
RPM
200
room burner fan RMP feedback alarm threshold
b6
10
120
sec
10
room burner fan RMP feedback alarm delay
b7
2500
6000
RPM
5000
boiler burner fan maximum RPM
b8
1500
4000
RPM
2500
boiler burner fan minimum RPM
b9
1000
3000
RPM
1000
boiler burner fan ignition RPM
b10
1
99
°C/°F (2)
10
proportional band for boiler temperature regulation
b11
2
10
sec
3
boiler ramp time
b12
200
1000
RPM
200
boiler burner fan RMP feedback alarm threshold
b13
10
120
sec
10
boiler burner fan RMP feedback alarm delay
b14
0
1
---
0
oven type 0 = electric, 1 = gas
Notes
(1)
Properly set the parameters corresponding to the regulators after setting parameter P1
(2)
the unit of measurement depends on P1
(3)
if the duration of the power cut is shorter than the time established with parameter r12, when the power supply is restored,
the cycle will be re-proposed from the start of the phase running during power cut.