2 starting a special cycle – EVCO EVCLC33DJ2 User Manual

Page 34

background image

EVCO S.p.A.

Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 34 of 66

The following table illustrates the factory settings of the timed

proofing cycle.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

30 °C

20... 50 °C

humidification

80 %.

40... 100 %.

duration

of

the

phase

120 min

1... 300 min

fan speed

minimum

air vent opening

on conclusion of the cycle

The following table illustrates the factory settings of the

environment cooling cycle; the opening and closing of the door

does not cause any consequence.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

50 °C

(param. r11)

0... 500 °C

fan speed

maximum,

without

inversion

of

rotation direction (if envisioned)

air vent opening

at the start of the cycle, for the

entire duration of the same

10.2

Starting a special cycle

Operate as follows to start a special cycle:

1.

Ensure that the device is switched on and that no

other procedure is in progress.

2.

Touch the "specials" key

3.

Touch the identification icon of the special cycle.

4.

Then touch

to start the

cycle

Note: In the picture on the left (Start a special cycle) the

special cycle refers to leavening, but the procedure is

the same as that for the start of all the remaining

special cycles: regeneration, cooling and cleaning.

Access to a special cycle.

Starting a special cycle.