beautypg.com

EVCO EVCLC33DJ2 User Manual

Page 48

background image

EVCO S.p.A.

Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204

page 48 of 66

PARAM.

MIN.

MAX.

U.M.

DEF.

FAN

F0

0

3

- - -

0

type of fan management

0

=

in “on/off” mode and at single speed

1

=

in “on/off” mode, with single speed and with inversion of the

direction of rotation of the fan

2

=

in “on/off” mode, with dual speed and with inversion of the

direction of rotation of the fan

3

=

in modulating mode and with inversion of the direction of

rotation of the fan

F1

5

120

s

15

duration of the fan switch-off due to the inversion of the direction of

rotation of the same (only if F0 = 1, 2 or 3); see also F2

F2

5

600

s

120

duration of the fan switch-on for every direction (only if F0 = 1, 2 or

3); see also F1

F3

0

1

- - -

0

temperature regulation output switch-off during fan switch-off due

to the effect of the inversion of the fan rotation direction (only if F0

= 1, 2 or 3)

0

= YES

F4

0

F5

%

0

minimum fan speed (intended as a percentage of the maximum

speed; only if F0 = 3)

F5

F4

100

%

100

maximum fan speed (intended as a percentage of the maximum

speed; only if F0 = 3)

F6

20/65

65/150

°C/°F (2)

60

temperature above which the technical compartment fan is

switched-on (referring to the temperature used by the control

module); see also F7

F7

1

99

°C/°F (2)

10

differential of F6

F8

0

100

%

10

Minimum speed that can be set by the fan user (intended as a

percentage of maximum speed; only if F0=3)

PARAM.

MIN.

MAX.

U.M.

DEF.

STEAM INJECTION

t0

0

2

- - -

0

steam generation mode

0

=

direct

1

=

with an external humidifier

2

=

combined (i.e. direct and with external humidifier)

t1

t2

999

s

60

cycle time for injection of the steam generated in direct mode

t2

0

t1

s

30

duration of the injection of the steam generated in direct mode

corresponding to the maximum humidification

This manual is related to the following products: