Flexuni/evc (pseudowire core connectivity, Bridge domain, pseudowire on svi) – Cisco OL-21636-01 User Manual
Page 317
A-39
Cisco IP Solution Center L2VPN and Carrier Ethernet User Guide, 6.0
OL-21636-01
Appendix A Sample Configlets
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain, Pseudowire on SVI)
FlexUNI/EVC (Pseudowire Core Connectivity, Bridge Domain,
Pseudowire on SVI)
Configuration
•
FlexUNI(EVC)/Metro Ethernet.
•
Feature: FlexUNI/EVC with pseudowire core connectivity, with bridge domain, and with
Pseudowire on SVI enabled on the N-PE.
•
Device configuration:
–
The N-PE is a Cisco 7600 with IOS 12.2(33) SRB3.
Interface(s): GigabitEthernet7/0/0.
–
The U-PE is a Cisco 3750ME with IOS 12.2(25) EY2.
Interface(s): FastEthernet1/0/10.
Configlets
Comments
•
None.
U-PE
N-PE
vlan 452
exit
!
interface FastEthernet1/0/10
no ip address
switchport trunk allowed vlan add 452
!
interface FastEthernet1/0/13
no spanning-tree bpdufilter enable
switchport
no keepalive
no ip address
switchport
switchport trunk encapsulation dot1q
switchport mode trunk
switchport trunk allowed vlan 452
switchport nonegotiate
vlan 3524
exit
!
ethernet evc Customer1_253
!
interface GigabitEthernet7/0/0
service instance 3 ethernet Customer1_253
encapsulation dot1q 452
rewrite ingress tag pop 1 symmetric
bridge-domain 3524 split-horizon
!
interface Vlan3524
no ip address
description BD=T,SVI=T,Flex
xconnect 22.22.22.22 52500 encapsulation
mpls
backup peer 22.22.22.22 52501
no shutdown