Run Circuit / Reverse Caution mode.

1.

With the key in Reverse Caution mode, A1 gets
power from the B terminal, just like the normal run
position.

2.

In addition, A2 is internally connected to the L termi-
nal. L is normally used for the lighting circuit.

2a.

In this case, a separate lighting circuit draws
power from A1

2b.

L is connected to the ground wire on the G ter-
minal by a jumper.

3.

The RMC module arms when it gets a ground signal
from A2 through the “A2 pwr” terminal on the RMC
module. See Figure 7.17.