Power Subsystems

System Event Log Troubleshooting Guide for EPSD

Platforms Based on Intel

®

Xeon

®

Processor E5 4600/2600/2400/1600/1400 Product Families

36

Intel order number G90620-002

Revision 1.1

Sensor Specific Offset

Description

Next Steps

Hex

Description

05h

Soft Power Control
Failure

Generally means power good was lost in
the system, causing a shutdown.

This could be cause by the power supply subsystem or system
components.

1. Verify all power cables and adapters are connected properly (AC

cables as well as the cables between the PSU and system
components).

2. Cross test the PSU if possible.

3. Replace the power subsystem.

06h

Power Unit Failure

Power subsystem experienced a failure.

Indicates a power supply failed.

1. Remove and reapply AC power.

2. If the power supply still fails, replace it.

4.3.2

Power Unit Redundancy Sensor

This sensor is enabled on the systems that support redundant power supplies. When a system has AC applied or if it loses
redundancy of the power supplies, a message will get logged into the SEL.

Table 17: Power Unit Redundancy Sensors Typical Characteristics

Byte

Field

Description

11

Sensor Type

09h = Power Unit

12

Sensor Number

02h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 0Bh (Generic Discrete)

14

Event Data 1

[7:6]

– 00b = Unspecified Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset as described in Table 18

15

Event Data 2

Not used

16

Event Data 3

Not used