1 node manager health event – next steps, Node manager health event, Next steps – Kontron S4600 SEL Troubleshooting User Manual
Page 129

System Event Log Troubleshooting Guide for EPSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
Manageability Engine (ME) Events
Revision 1.1
Intel order number G90620-002
119
Byte
Field
Description
If Error type = 11
If Error type = 12
Otherwise set to 0.
13.3.1
Node Manager Health Event – Next Steps
Misconfigured policy can happen if the max/min power consumption of the platform exceeds the values in policy due to hardware
reconfiguration.
First occurrence of not acknowledged event will be retransmitted no faster than every 300 milliseconds.
Real-time clock synchronization failure alert is sent when NM is enabled and capable of limiting power, but within 10 minutes the
firmware cannot obtain valid calendar time from the host side, so NM cannot handle suspend periods.
Next steps depend on the policy that was set. See the Node Manager Specification for more details.