Kontron S4600 SEL Troubleshooting User Manual

Page 139

background image

System Event Log Troubleshooting Guide for EPSD

Platforms Based on Intel

®

Xeon

®

Processor E5 4600/2600/2400/1600/1400 Product Families

Microsoft Windows* Records

Revision 1.1

Intel order number G90620-002

129

Table 104: Bug Check/Blue Screen code OEM Event Record Typical Characteristics

Byte

Field

Description

1

2

Record ID

ID used for SEL Record access

3

Record Type

[7:0]

– DEh = OEM timestamped, bytes 8-16 OEM defined

4

5

6

7

Timestamp

Time when the event was logged. LS byte first.

8

9

10

IPMI Manufacturer ID

0137h (311) = IANA enterprise number for Microsoft

0157h (343) = IANA enterprise number for Intel

The value logged depends on the Intelligent Management Bus Driver (IMBDRV) that is loaded.

11

Sequence Number

Sequential number reflecting the order in which the records are read. The numbers start at 1 for the first entry in the SEL
and continue sequentially to n, the number of entries in the SEL.

12

13

14

15

Bug Check / Blue Screen
Data

The first record of this type contains the Bug Check / Blue Screen Stop code and is followed by the four Bug Check / Blue
Screen parameters. LSB first.

Note that each of the Bug Check / Blue Screen parameters requires two records each.

Both of the two records for each parameter have the same Record ID.

There is a total of nine records.

16

Operating system type

00 = 32-bit OS

01 = 64-bit OS