1 smi timeout – next steps, 3 system event log cleared, Smi timeout – Kontron S4600 SEL Troubleshooting User Manual
Page 113: Next steps, System event log cleared

System Event Log Troubleshooting Guide for EPSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
Miscellaneous Events
Revision 1.1
Intel order number G90620-002
103
11.2.1
SMI Timeout – Next Steps
This event normally only occurs after another more critical event.
1. Check the SEL for any critical interrupts, memory errors, bus errors, PCI errors, or any other serious errors.
2. If these are not present, the system locked up before it was able to log the original issue. In this case, low level debug is normally
required.
11.3 System Event Log Cleared
The BMC logs a SEL clear event. This is only ever the first event in the SEL. Cause of this event is either a manual SEL clear using
selview or some other IPMI-aware utility, or is done in the factory as one of the last steps in the manufacturing process.
This is an informational event only.
Table 80: System Event Log Cleared Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
10h = Event Logging Disabled
12
Sensor Number
07h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6]
– 00b = Unspecified Event Data 2
[5:4]
– 00b = Unspecified Event Data 3
[3:0]
– Event Trigger Offset = 2h = Log area reset/cleared
15
Event Data 2
Not used
16
Event Data 3
Not used