beautypg.com

1 smi timeout – next steps, 3 system event log cleared, Smi timeout – Kontron S4600 SEL Troubleshooting User Manual

Page 113: Next steps, System event log cleared

background image

System Event Log Troubleshooting Guide for EPSD

Platforms Based on Intel

®

Xeon

®

Processor E5 4600/2600/2400/1600/1400 Product Families

Miscellaneous Events

Revision 1.1

Intel order number G90620-002

103

11.2.1

SMI Timeout – Next Steps

This event normally only occurs after another more critical event.

1. Check the SEL for any critical interrupts, memory errors, bus errors, PCI errors, or any other serious errors.
2. If these are not present, the system locked up before it was able to log the original issue. In this case, low level debug is normally

required.

11.3 System Event Log Cleared

The BMC logs a SEL clear event. This is only ever the first event in the SEL. Cause of this event is either a manual SEL clear using
selview or some other IPMI-aware utility, or is done in the factory as one of the last steps in the manufacturing process.

This is an informational event only.

Table 80: System Event Log Cleared Sensor Typical Characteristics

Byte

Field

Description

11

Sensor Type

10h = Event Logging Disabled

12

Sensor Number

07h

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 6Fh (Sensor Specific)

14

Event Data 1

[7:6]

– 00b = Unspecified Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset = 2h = Log area reset/cleared

15

Event Data 2

Not used

16

Event Data 3

Not used