The SCSI Interface
Chapter 3
Setting the SCSI Controller Card Configuration
The DIP switches, shown in Figure 3.11 are used to set the HO address for the
SCSI host card.
I/O Address
SWl
SW2
350h
OFF
OFF
340h
OFF
ON
250h
ON
OFF
240h
ON
ON
Table 3.3 The SCSI controller card’s configuration block switch settings.
Please note the following, regarding the SCSI controller card configuration:
• A single 8k address range beginning at the address selected is used.
• Switches 3-4-5 control the BIOS ROM address.
• No BIOS is included with this interface card.
• Switch 6 controls boot disk operation. This is not applicable with Coolscan.
• Switch 7 and 8 should remain OFF at all times.
• JP2 controls the Zero wait state operation.
• JP3 controls the optional interrupt selection. As shipped, the SCSI controller card
does not require any interrupt setting. If you have a conflict with another interface
card or software you should assign an unused interrupt to the SCSI card. The avail
able interrupts are IRQ3, IRQ5 and IRQ7. The jumper settings are printed on the
SCSI card.
•
• JP4 provides a connection for an external LED indicator (not included) to indicate
SCSI bus activity. If for some reason Coolscan is not visible to you while scanning,
you may wish to connect an additional activity LED to the top two pins.