beautypg.com

Unitec Wash Select II POS Owner’s Manual User Manual

Page 136

background image

W A S H S E L E C T I I

Document Number:

WS21002

122

Document Title:

WSII Operations Manual

menu); the programmed token value is internally multiplied by the number of pulses sent by
the IDX.

(Example: If you have assigned a token value of $.50 under t

he “Cash & Tokens” menu, and

you have four different tokens, each token must be worth a multiple of $.50. or as follows
token 1 = $.50, token 2 = $1.00 token 3 = $1.50 and token 4 = $2.00. As you can see each
token in this example represents numbers that can be divided by $.50.) The Wash Select II
does not keep a separate accounting of each different token your site may have; it just keeps
a running total equal to the total dollar value entered. This total will be reflected on the Wash
Select II accounting report.

To program the IDX to accept a single token, follow the instructions below. If more tokens are
required, refer to Table 23 to get the switch locations for that particular token, and then
depress the push-button the number of times that is equal to the number of pulses to be
output for that token.

1.

Locate the rotary-switch and set it to position 1, 2, 3, or 4.

2.

Press the button immediately to the left of the rotary-switch one or more times
depending on the number of pulses you want that token to send.

3.

Drop six sample tokens through the coin slot one at a time, and verify that the red
light (LED) blinks several times after the last token has been entered.

4.

Reset the rotary-

switch to “0”, and then replace the front cover.

Now assume your token value is set for $1.00. To program the IDX acceptor to accept two
different tokens, token number 1 for $1.00 and token number 2 for $2.00, follow the steps
below.

1.

Set the rotary-

switch to position “1”.

2.

Press the button directly to the left one time.

3.

Drop six sample tokens into the coin slot one at a time, and verify that the light
(LED) blinks several times after the last token is entered.

4.

Now set the rotary-

switch to position “2”.

5.

Press the button directly to the left of the rotary-switch twice (for two pulses or $2).

6.

Drop six sample tokens of the second type into the coin slot one at a time, and
verify that the light (LED) blinks several times after the last token is entered.

7.

Return the rotary-

switch to the “0” position.

8.

Replace the cover.