beautypg.com

Pos4000 link, Table 14. wash select ii-pos40000 wiring – Unitec Wash Select II POS Owner’s Manual User Manual

Page 107

background image

W A S H S E L E C T I I

Document Number:

WS21002

93

Document Title:

WSII Operations Manual

2.

Using the (3) key to scroll forward and the (1) key to scroll back, scroll through the
main menu until the “VIP Wash Pass” option is displayed. Press the (*) key to
enter.

3.

Scroll through

this menu until the “Coupon Limit” option is displayed, and then

press the (*) key to enter.

4.

Press the (1) key to limit one per customer, or the (3) key for no limit.

Default: Disabled (no limit).

2.16 POS4000 Link

The Wash Select II may be configured to interface to a POS4000 in order to be activated by
codes sold at one or multiple POS4000 units. This is how a Wash Select II/POS is configured
to operate. Any Wash Select II may also be upgraded in the field to interface to a POS4000
either by direct wires or via encrypted codes from a Remote Code POS4000. The Wash
Select II can support having BOTH a direct (wired) POS4000 link AND Remote Code
POS4000s enabled on the unit. When both types of POS4000 links are enabled, we highly
suggest that different code lengths are assigned to the linked POS4000 and to the Remote
Code POS4000 to limit the chance of duplicate codes being generated. A code will first
attempt to be verified by the Remote Code POS4000, then it will be sent to the linked
POS4000 for verification. For information on enabling and programming for the Remote Code
POS4000, please refer to Section 2.8.12.

The POS4000 Link menu allows the Wash Select II to be configured to interface with a
POS4000. In addition, it provides the activation of the Multi-Unit Fleet option.

Once the Wash Select II is properly configured, codes can be sold at one or more POS4000
units to be used at the Wash Select II. Configuring of these settings is also necessary for
units that are equipped for authorization through the POS network. In this case, set the
interface mode to ‘1’. If you have multiple Wash Select II units, you will also need to set the
bay address for each Wash Select II.

The following instructions show how to set up the Wash Select II unit to interface to the
POS4000.

1.

If not already installed, with the power disconnected, install the Wash Select II
communications module onto the top left hand corner of the CPU board. The
board is installed with LED’s on the bottom.

2.

Restore power to the Wash Select II and place the unit in setup mode. If you have
more than one bay, set the units up one at a time, with all un-configured units
turned off.

3.

Wire the POS4000 cable connections as per the following connections:

Table 14. Wash Select II-POS40000 Wiring

POS4000

Wash Select II

connector J22

Pin 1

– White

Pin 1

– White

This manual is related to the following products: