Special Controller Functions

Appendix C

DTAM Micro

C–2

The Special Menu provides access to these functions:

1 P-A/D refer to page C–2 for more information.

2 Mode refer to page C–18 for more information.

3 Mem Xfer refer to page C–19 for more information.

4 Clr Fault refer to page C–20 for more information.

Use the P-A/D function to display and change values in controller files. The
only exceptions are Input and Output files, you cannot write to these file
types. The P-A/D function is often useful when starting up or debugging
applications.

The following tables list the controller file types that can be accessed using
the P-A/D function:

SLC File Types

File Type

Identifier

Default File

Number

Read

Write

Output

O

0 (fixed)

Yes

No

Input

I

1 (fixed)

Yes

No

Status

S

2 (fixed)

Yes

Yes

Binary

B

3

Yes

Yes

Timer

T

4

Yes

Yes

Counter

C

5

Yes

Yes

Control

R

6

Yes

Yes

Integer

N

7

Yes

Yes

PLC-5 File Types

File Type

Identifier

Default File

Number

Read

Write

Output

O

0 (fixed)

Yes

No

Input

I

1 (fixed)

Yes

No

Status

S

2 (fixed)

Yes

Yes

Binary

B

3

Yes

Yes

Timer

T

4

Yes

Yes

Counter

C

5

Yes

Yes

Control

R

6

Yes

Yes

Integer

N

7

Yes

Yes

ASCII

A

None

Yes

Yes

BCD

D

None

Yes

Yes

Message

MG

None

Yes

Yes

ASCII String

ST

None

Yes

No

Using the P-A/D Function