Special functions for controller operations – Rockwell Automation 2707-M232P3_M485P3 DTAM Micro Operator Interface Module User Manual
Page 31
Chapter 3
Initial Setup and Mode Menu
3–7
The Special Menu item provides access to special features for the controller
operations. A security access code may be assigned in the application
restricting access to the Special Menu.
Select Special from the Mode Menu.
1 Reset
3 Special
2 Com-Port
4 Other
This menu displays:
1 P-A/D
3 Mem Xfr
2 Mode
4 Clr Fault
Note: Below are brief descriptions of each menu item.
Refer to Appendix C for instructions on using the Special Menu items.
P-A/D
Use the Point Access / Display function to display, and modify controller
data files. The P-A/D function does not allow you to write controller Input
and Output files. Appendix C provides a listing of the applicable file types
for SLC and PLC-5 controllers along with step-by-step instructions.
Mode
Select mode to place the controller in either the run or program modes. This
may be useful if you need to halt the controller for memory transfers.
Mem Xfer
Use the memory transfer function to initiate a transfer of data between a
memory module and an SLC or PLC controller. Memory transfers with a
PLC-5 are only to a memory module, you cannot transfer data from a
memory module to a PLC-5. Appendix C describes how to use the Mem
Xfer function.
Clr Fault
Use the Clear Fault function to clear all major and minor faults in the
controller.
Special Functions for
Controller Operations