Rockwell Automation 1794-OF8IH FLEX Isolated Input/Output HART Analog Modules User Manual
Page 8

Publication 1794-UM065B-EN-E - September 2010
ii Table of Contents
Connections for the 1794-OF8IH HART Analog Output Module
on a 1794-TB3 or 1794-TB3S Terminal Base Unit . . . . . . . . . . . . 24
Input, Output and Configuration of
the FLEX I/O HART Analog I/O
Modules
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Use Programming Software in Your FLEX I/O Application . . . . . . . 25
About the ControlNet and EtherNet Adapters . . . . . . . . . . . . . . . . . . 26
Communication Over the FLEX I/O Backplane . . . . . . . . . . . . . . . . 26
Communication Fault Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Idle State Behavior. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1794-IF8IH and 1794-OF8IH
Configuration
Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Fault Mode (8 of 1 bit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Input Filter Cutoff (8 of 3 bits). . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
ADC Conversion Rate, Channel Update Time and Repeatability. 39
Data Format (8 of 4 bits). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Remote Low Low Alarm Limit (8 of 16 bit) . . . . . . . . . . . . . . . . . 41
Remote High High Alarm Limit (8 of 16 bit). . . . . . . . . . . . . . . . . 42
Low Alarm Limit (8 of 16 bit). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
High Alarm Limit (8 of 16 Bit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
HART Disable Channel 0 to 7 (8 of 1 bit) . . . . . . . . . . . . . . . . . . . 43
HART Current Fault Limit (8 of 5 bits) . . . . . . . . . . . . . . . . . . . . . 43
Command 3 Disable (8 of 1 bit) . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Real Time Data (RTD) Profile, Primary Input Parameters . . . . . . . . . 45
Primary Input Data (8 of 16 bits each) . . . . . . . . . . . . . . . . . . . . . . 45
Real Time Data (RTD) Profile, Primary Status Parameters . . . . . . . . . 46
Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
High Alarm (8 of 1 bit each) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Low Alarm (8 of 1 bit each) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Remote Alarm (8 of 1 bit each). . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Loop Alarm (8 of 1 bit each). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Module Diagnostic Status (1 of 8 bits) . . . . . . . . . . . . . . . . . . . . . . 49
HART Status Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
HART Failure (8 of 1 bit each) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
HART Current Fault (8 of 1 bit each) . . . . . . . . . . . . . . . . . . . . . . 52
HART Transmitter List (8 of 1 bit each) . . . . . . . . . . . . . . . . . . . . 52
Secondary Input Data Table, Cyclic EDT Input Data. . . . . . . . . . . . . 52