Motor thermal capacitance, winding to ambient, Motor model – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 97
Publication 2098-RM003A-EN-P October 2001
Command Reference
2-81
Motor Thermal Capacitance, Winding to Ambient
Motor Model
Format:
:aa0E9fddddddddcc
Parameter
Code:
0x0E9
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dddddddd
Thermal capacitance of the motor from winding to
ambient, in units of Watt-second/degrees C * 256.
Minimum
Value:
0x00000001
Maximum
Value:
0x7FFFFFFF
Default:
0x0004CB00
Format:
:aa0EBfdd…ddcc
Parameter
Code:
0x0EB
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x08 = Invalid Function Code
Data Fields:
dd…dd
Motor model text, a 32-character string.
Default:
" "