beautypg.com

Preset velocity accel/decel limit enable/disable – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual

Page 45

background image

Publication 2098-RM003A-EN-P October 2001

Command Reference

2-29

Preset Velocity Accel/Decel Limit Enable/Disable

Format:

:aa0A9fddcc

Parameter
Code:

0x0A9

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dd

Enable/disable control for preset velocity
acceleration limits, where:
0x00: Disable preset accel/decel limits
0x01: Enable preset accel/decel limits.

Minimum
Value:

0x00

Maximum
Value:

0x01

Default:

0x01