Format:

:aa0B4fnnddddcc

Parameter
Code:

0x0B4

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
0xA = Read Minimum Array Index Value
0xB = Read Maximum Array Index Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x07 = Invalid Array Index
0x08 = Invalid Function Code

Data Fields:

nn

Array index

dddd

Index dwell for the specified index, in units of
milliseconds.

Minimum
Value:

0x0000

Maximum
Value:

0xFFFF

Minimum Array
Index Value:

0x00

Maximum Array
Index Value:

0x3F

Default: