2-24

Command Reference

Analog Deceleration Limit

Format:

:aa05Efddddddddcc

Parameter
Code:

0x05E

Valid Function
Codes:

0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value

Valid Exception
Codes:

0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code

Data Fields:

dddddddd

Analog deceleration limit, in units of counts/sec/
sec.

Minimum
Value:

0x00000000

Maximum
Value:

0x7FFFFFFF

Default: