Machine cycle size, Position rollover enable/disable – Rockwell Automation 2098-DSD-xxx Ultra3000 Host Commands for Serial Interface User Manual
Page 32

Publication 2098-RM003A-EN-P October 2001
2-16
Command Reference
Machine Cycle Size
Position Rollover Enable/Disable
Format:
:aa193fddddddddcc
Parameter
Code:
0x193
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dddddddd
Machine cycle rollover position, in units of counts.
Minimum
Value:
0x00000064
Maximum
Value:
0x7FFFFFFF
Default:
0x7FFFFFFF
Format:
:aa194fddcc
Parameter
Code:
0x194
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields:
dd
Enables or disables the rollover of position variables
according to the machine cycle size parameter.
Minimum
Value:
0x00
Maximum
Value:
0x01
Default:
0x01