beautypg.com

Communication over the flex i/o backplane, Communication over the, Flex i/o backplane -3 – Rockwell Automation 1794-OE8H FLEX I/O HART Analog Modules User Manual User Manual

Page 63: Scheduled data transfer -3, Scheduled data transfer

background image

Publication 1794-UM063A-EN-P - March 2006

Input, Output and Configuration Files for the Analog I/O Modules on the ControlNet Network 4-3

Communication Over the
FLEX I/O Backplane

One 1794-ACNR15/B ControlNet adapter can interface up to eight terminal
base units with installed FLEX I/O modules, forming a FLEX I/O system of
up to eight slots.

The adapter communicates to other network system components (typically
one or more controllers, scanners, or programming terminals) over the
ControlNet network. The adapter communicates with its I/O modules over
the FLEX I/O backplane.

Configuration data is not continuously updated to the module.

Scheduled Data Transfer

Scheduled data transfer:

• is continuous.

• is asynchronous to the controller program scan.

• occurs at the actual rate displayed in the Actual Packet Interval field on

the programming software ControlNet I/O mapping (monitor) screen.

I/O Module

I/O Module

I/O Module

Configuration

Configuration

Configuration

Inputs

Inputs

Inputs

Status

Outputs

Status

Status

Outputs

Outputs

Read
Words

Write
Words

0

X

Slot 0

Slot 1

Slot 7

Network

ControlNet
Adapter

Read

Write

41626