beautypg.com

Acceleration feedforward gain - kaff, Position compare 1 max, Position compare 2 max – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 86: Velocity error time, Position error limit, Position error time, R 112 (position compare 1 max), fo, R 113 (position compare 2 max, 112 - position compare 1 max, Re than position compare 1 max

background image

Publication 2098-RM004A-EN-P – August 2002

2-70

Programming Reference

107

Set

Velocity Error
Time

UINT

2

mSec

The minimum time which the velocity error must be
greater than the Velocity Error Limit to cause a
Velocity Error Fault.
Range: 0 to 65535
Default: 1000

108

Set

Position Error
Limit

UDINT

4

Cnts

The minimum position error which triggers the
Following Error fault.
Range: 0 to 0x7fffffff
Default: 8000

109

Set

Position Error
Time

UINT

2

mSec

The minimum time during which the position error
must be greater than the Position Error Limit to
cause a Following Error fault.
Range: 0 to 65535
Default: 100

110

Set

Analog Output
Position Scale

DINT

4

Cnts/V

This parameter is used to scale the analog output
when Parameter 98 - Analog Output Configuration
selects a position signal and Parameter 99 - Analog
Output Scale i
s equal to zero.
Range: -0x7fffffff to 0x7fffffff
Default: 0

111

Set

Acceleration
Feedforward
Gain - Kaff

UINT

2

%

Acceleration feedforward gain for the position loop.
The Kaff gain generates a feed forward signal
proportional to the commanded acceleration.
Kaff gain reduces position following error. However,
high values can cause position overshoot.
Range: 0 to 200
Default: 0

112

Set

Position Compare
1 Max

DINT

4

Cnts

The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 1 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0

113

Set

Position Compare
2 Max

DINT

4

Cnts

The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 2 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description