beautypg.com

Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 26

background image

Publication 2098-RM004A-EN-P – August 2002

2-10

Programming Reference

5

Get

Allocation
information

STRUCT of:
BYTE

USINT

Allocation choice
(1 byte)

+ Master MAC
ID (1 byte)

Refer to the
DeviceNet Object
definition in the
DeviceNet
Specification

Range 0-63, 255
Modified via
Allocate only.

6

MAC ID
Switch
Changed

BOOL

The Node
Address
switch(es) have
changed since
last
power-up/reset.

0 = No change
1 = Change since
last reset or
power-up

7

Baud Rate
Switch
Changed

The Baud Rate
switch(es) have
changed since
last
power-up/reset.

0 = No change
1 = Change since
last reset or
power-up

8

MAC ID
Switch
Value

USINT

Actual value of
Node Address
switch(es) or
EEPROM value if
programmable.

Range 0-63

9

Baud Rate
Switch
Value

Actual value of
Baud Rate
switch(es),
EEPROM value if
programmable, or
operating value
after an autobaud
was completed.

Range 0-2

DeviceNet Object,
Common Services

Service
Code

Service
Name

Service
Description

0E

H

Get_Attribute_Single

Returns the contents of the
specified attribute.

10

H

Set_Attribute_Single

Modifies the specified attribute.

DeviceNet Object,
Attributes of Instance ID = 1 (Continued)

Attr.
ID

Access
Rule

Attribute
Name

Data Type

Description

Semantics
of Values