Read Data From the CFM Module

When configured for QRC module emulation, BTR programming
moves three words from the CFM module to the PLC processor’s
data table. The following BTR assignments apply when the CFM
module is configured for QRC module emulation.

BTR

Bit

BTR

Word

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Block ID

ЙЙЙ

1

ЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙЙ

Header

Input Channel Rate

2

Rate of Ratemeter A

3

Rate of Ratemeter B

*ALL numeric values are in binary*

BTR Word Descriptions

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Header will be 7001 Hex or 28,673 binary. Identifies the

module as a CFM (QRC) module.

word 1

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

Rate Ċ indicates the calculated rate.

RANGE: 0Ć15,800Hz binary

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

word 2 (ratemeter A)

0

0

0

0

0

0

0

0

0

0

0

1

0

1

1

1

The rates in words 2 & 3 are updated every 13.5msĆ20ms

maximum. The greater the frequency, the faster the

update time. The accuracy of the returned rate is

±

1Hz.

Rates: 0Ć169Hz are reported as zero

170Ć15,800Hz are reported as calculated

> 15,800Hz are reported as 15,800