Rockwell Automation 1769-XXXX Compact I/O Modules User Manual
Page 67
Rockwell Automation Publication 1769-IN088A-EN-P - February 2011
67
I/O Memory Mapping Chapter 3
5
SGN
Process Alarm Low Data Value Channel 0
0
6
SGN
Alarm Dead Band Value Channel 0
0
7
Reserved
8
EC
Reserved
EA
AL
EI
Reserved
Input Filter Sel ChI1
9
Reserved
Input Dta Fm
ChI1
Reserved
Inpt Tp/Rnge Sel
ChI1
10
SGN
Process Alarm High Data Value Channel 1
0
11
SGN
Process Alarm Low Data Value Channel 1
0
12
SGN
Alarm Dead Band Value Channel 1
0
13
Reserved
14
EC
Reserved
EA
AL
EI
Reserved
Input Filter Sel ChI2
15
Reserved
Input Dta Fm
ChI2
Reserved
Inpt Tp/Rnge Sel
ChI2
16
SGN
Process Alarm High Data Value Channel 2
0
17
SGN
Process Alarm Low Data Value Channel 2
0
18
SGN
Alarm Dead Band Value Channel 2
0
19
Reserved
20
EC
Reserved
EA
AL
EI
Reserved
Input Filter Sel ChI3
21
Reserved
Input Dta Fm
ChI3
Reserved
Inpt Tp/Rnge Sel
ChI3
22
SGN
Process Alarm High Data Value Channel 3
0
23
SGN
Process Alarm Low Data Value Channel 3
0
24
SGN
Alarm Dead Band Value Channel 3
0
25
Reserved
26
EC
Reserved
EHI ELI
LC
ER
FM
PM 0
PFE
27
Reserved
Outpt Fm ChI0
Reserved
Outpt Tp/Rnge Sel
ChI0
28
SGN
Fault Value Channel 0
0
0
29
SGN
Program (Idle) Value Channel 0
0
0
30
SGN
Clamp High Data Value Channel 0
0
0
31
SGN
Clamp Low Data Value Channel 0
0
0
32
SGN
Ramp Rate Channel 0
0
0
33
Reserved
34
EC
Reserved
EHI ELI
LC
ER
FM
PM 0
PFE
35
Reserved
Outpt Fm ChI1
Reserved
Outpt Tp/Rnge Sel
ChI1
36
SGN
Fault Value Channel 1
0
0
37
SGN
Program (Idle) Value Channel 1
0
0
38
SGN
Clamp High Data Value Channel 1
0
0
Wo
rd
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0