I/O Memory Mapping Chapter 3

Module Default Condition

The modules default condition is all zeros, programming the conditions shown
below.

1769-OB16P

The following I/O memory mapping lets you configure the 1769-OB16P
module.

Output Module’s Input Data File

For each module, slot

x, input data file word 0 contains the state of the module’s

output data (output data echo) file word 0. During normal operation, these input
bits represent the logic state that the outputs are directed to by the control
program. They are also dependent upon these configurations:

• Program mode

(1)

configuration, if supported by the controller

• Fault mode

(1)

configuration, if supported by the controller

Word or Bit Affected

Condition Applied

Word 0, Bit 0:

Program-to-Fault Enable

Program Value

Word 1:

Program State

User-defined Safe State

Word 2:

Program Value

Off

Word 3:

Fault State

User-defined Safe State

Word 4:

Fault Value

Off

(1) Not supported by MicroLogix 1500.

Wo

rd

Bit Position

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

0

r

(1)

(1) r= read.

r

r

r

r

r

r

r

r

r

r

r

r

r

r

r

IMPORTANT

The output module’s input data file reflects the output data echo of the
module, not necessarily the electrical state of the output terminals. It
does not reflect shorted or open outputs.

TIP

It is only important to use this input word if the controller/adapter
supports the Program mode or Fault mode function, and if it is configured
to use them.