Rockwell Automation 1336 8A-48A Fiber Industry User Manual
Page 89
5–23
Programming
[FStart Reverse]
This value sets the frequency at which the reverse
speed search begins. If this value exceeds
[Maximum Freq], speed search will begin at
[Maximum Freq]. Reverse search ends at zero Hertz
or when motor speed is found.
Parameter Number
157
Parameter Type
Read and Write
Display Units / Drive Units
1 Hertz / Hertz
Factory Default
0 Hz
Minimum Value
0 Hz
Maximum Value
400 Hz
[Traverse Inc]
This value sets the traverse increase time
independently. See figure below.
Parameter Number
78
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Sec / Seconds x 100
Factory Default
0.00 Sec
Minimum Value
0.00 Sec
Maximum Value
30.00 Sec
[Traverse Dec]
This value sets the traverse decrease time
independently. See figure below.
Parameter Number
172
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Sec / Seconds x 100
Factory Default
0.00 Sec
Minimum Value
0.00 Sec
Maximum Value
30.00 Sec
[Max Traverse]
This value sets the peak amplitude of speed
modulation.
Parameter Number
79
Parameter Type
Read and Write
Display Units / Drive Units
0.01 Hertz / 32767 = [Maximum Freq]
Factory Default
0.00 Hz
Minimum Value
0.00 Hz
Maximum Value
50% of [Maximum Freq]
Seconds
Hertz
Maximum Traverse (–)
Traverse
P-Jump
P-Jump (+)
P-Jump (–)
Output
Reference
Traverse Period
–20
0
10
20
30
40
50
60
20
40
Maximum Traverse (+)
Traverse Function
Feature Select