Installing the Option Module
Chapter 2
When Operating in Tap Mode (only PowerFlex 755 drives)
1.
Remove power from the drive.
2.
Remove the drive cover and lift up the drive HIM bezel to its open
position to access the drive control pod.
3.
Use static control precautions.
4.
Connect the short Ethernet cable (provided with the option module)
between the option module’s ENET3 (DEVICE) port and the Ethernet
port on the PowerFlex 755 drive’s embedded EtherNet/IP adapter (see
). (ENET1 and ENET2 ports are used for linear or DLR network
topology as shown in
Figure 6 - Connecting the Short Ethernet Cable for Tap Mode of Operation
ATTENTION: Risk of injury or death exists. The PowerFlex drive may contain high
voltages that can cause injury or death. Remove power from the drive, and then
verify power has been discharged before connecting the option module to the
network.
0
5
4
9
3
8
2
7
1
6
0
5
4
9
3
8
2
7
1
6
0
5
4
9
3
8
2
7
1
6
PowerFlex 755 Drive Control Pod
(drive shown with cover removed)
Ethernet Port on
PowerFlex 755 Drive
Embedded EtherNet/IP
Adapter
Option Module’s
ENET3 (DEVICE) Port
(bottom port
from top of card)
Short Ethernet Cable
(provided with option module; spare part
catalog number 1585J-M8CBJM-0M3)