4. Press Run to start auto-tuning.

The controller displays the following (or a similar) message:

“The ‘Mode to Tune’ (‘Force’) is not the control mode which will be active
during auto-tuning. Ensure that the active ‘Control Mode’ is tuned prior to
proceeding. If the selected ‘Mode to Tune’ requires feedback from a
specimen (ex: Force/Torque/Strain), ensure that a specimen is mounted.”

Select Yes (or Press <>) if you have tuned the channel’s displacement
mode and installed a specimen.

When the Controller starts auto-tuning the following is displayed:

“Auto Tuning in Progress...To terminate auto-tuning before
completion, press .”

When auto-tuning is complete, the controller displays:

“Auto Tuning for this mode has completed successfully.”

Also, when auto-tuning is complete, the results are displayed showing
Current tuning values and Reference values.

Press Accept to apply the Reference values.

5. Save the auto-tuning values.

Standalone FlexTest SE Controllers: Select Setup > Open/Save
Parameters
> <>

Automated Controllers: In the Station Manager window’s File menu,
select Save Parameters to save the New Values.

You may save auto-tuning values to an existing parameter set or to a new
parameter set.

How to improve auto-

tuning results

You can attempt to further improve tuning using the following techniques:

Use the auto-tuning settings as a starting point when manually tuning each
control mode.

If your feedback signal is noisy, use a tuning filter (see

“About Tuning

Filters”