beautypg.com

MTS Series 793 User Manual

Page 55

background image

How To Warm Up Station Hydraulics

MTS Series 793 Tuning and Calibration

Tuning Procedures

55

7. Observe actuator response. If necessary, correct P Gain during warm up.

If the actuator responds in a sluggish manner, increase the P Gain setting. If
you hear an unusual or unexpected sound, decrease the P Gain.

Standalone FlexTest SE Controllers:

Select Tuning > Manual > P Gain.

Automated Controllers:

A. On the Station Manager window’s Display menu, select Station Setup.

B. Click the Channel Tuning icon to open the Tuning panel, the click the

Adjustments tab to display the P Gain control.

8. After 30 minutes, click Stop.

9. Remove hydraulic pressure from the station.