Parameter data transfer

Lenze parameter sets
Parameter sets for Drive PLC and ECSxS / ECSxA axis modules

8

l

86

EDSMF2133IB EN 5.0

8.1.4

Parameter sets for Drive PLC and ECSxS / ECSxA axis modules

The Drive PLC and ECSxS / ECSxA axis modules each have a parameter set for storage in the
EEPROM. Another parameter set is stored in the main memory. This parameter set is called
"current" parameter set.

Addressing

l

Only the current parameter set can be directly addressed via the bus.

l

After switch−on, parameter set 1 is automatically loaded in the current parameter set.

)

Note!

Changes within the current parameter set are lost after the controller is
switched off.
Code C0003 serves to save the current parameter set (see documentation of
the controller).