4 technical data, 1 general data, Technical data – Lenze EMF2133IB User Manual
Page 16: General data, 4technical data

Technical data
General data
4
l
16
EDSMF2133IB EN 5.0
4
Technical data
4.1
General data
Area
Values
Order designation
EMF2133IB
PNO ID number
2133
hex
Communication profile
(DIN 19245 Part 1 and Part 3)
l
PROFIBUS−DP−V0
l
PROFIBUS−DP−V1
Communication medium
RS485
Interface
9−pin Sub−D socket
Drive profile
l
DRIVECOM profile "drive technology 20" (can be switched off)
l
PROFIdrive profile (can be switched off, state machine and PROFIdrive
parameter data channel)
Network topology
l
without repeaters: Line
l
with repeaters: Line or tree
PROFIBUS nodes
Slave
Baud rate [kbps]
9.6 ... 12000 (automatic detection)
Process data words
1 ... 12 words
(16 bits/word)
DP user data length
1 ... 12 process data words +
4 parameter data words
Max. number of stations
l
Standard: 32 (= 1 bus segment)
l
with repeater: 125
Max. cable length per bus
segment
1200 m (depending on the baud rate and cable type used)
External DC voltage supply
V = +24 V DC ±10 %
I = 120 mA
,
Documentation for Lenze series of devices 8200 vector, 9300 and ECS
Here you can find the ambient conditions and the electromagnetic