This chapter describes the procedure for program preparation and actual
program examples for printing data.

4.1 Printing Position Specification

The origin for positioning bar codes or characters to be printed on labels
is at the bottom left of label, and with the distance from that point, the
printing position is designated.

The distance upward from the point is called the row address, while the
distance rightward from the point is called the column address. Units of
0.01 inch or 0.1 mm are used. Changing units is provided with the m
command. In this explanation, the address is specified in 0.1 mm units.

Relevant command: m

After receiving this command, all length specification commands are in 0.1
mm units.

AB

Origin

Column address

Row address

The origin for row address is 2 mm from the top of the paper.