Bar code W1F / W1f:

AZTEC

This is 2-dimentional and variable length bar code. Variable length bar codes can be
generated by specifying their bar code type.

W1F

:Data amount should be set by 4-digit bytes

W1f

:Data amount is automatically set.

The input data is comprised of 5 elements.

4 digits--

Amount of data to be used when W1F is specified.
Bytes following this value should be specified.
(Including 4 bytes for ECI and EC setting.)
When W1f is specified, the field is blank.


1 digit--

ECI function

0:Invalid

1:Valid


3 digits--

EC setting
Error correction and specification of amount of printable data
(Setting range: 000 – 300)

Set value

Error correction ratio

000

: 23%

001 – 099

: % of specified value

100 – 104

:Compact 1 to 4 layers

201 – 232

:Full size 1 to 32 layers

300

:Decimal numbers 0 to 255 should be
specified.
(AZTEC code of 1-byte data is generated.)

Variable length-- Data character string

In the case of WIF specification, the number of characters will be
those obtained by subtracting the total of 4 bytes for ECI function
and error correction designation from the number of bytes initially
set.



Bar code ESC enhancing + M:

Matrix 2 of 5

This is a bar code comprised of only numeric numbers and the number of digit has
variable length. The standard ratio is 5:2. When using this bar code, the bar code
type should be specified as [ESC] and add “M” at the head of the data part.