JLG 4017PS Service Manual User Manual
Page 262
Electrical System
9-104
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
1478
524037
4
Ashlamp; short circuit to ground
1479
524062
12
Regeneration inhibit switch not available; Com Inh Swt NA
1480
524062
12
Regeneration release switch not available; Com Reg Swt NA
1481
524025
5
DPF system; operating voltage error
1482
524044
9
CAN message ComMS_Sys7 not received from slave
1483
523632
2
Metering control is not performed in time error
1484
524068
2
Master ECU and Slave ECU have been identified as the same
types
1485
524052
11
Master ECU and Slave ECU data sets or software are not identical
1490
4376
5
6-6-7
SCR reversing valve; open load
1491
4376
12
6-6-7
SCR reversing valve; over temperature
1493
4376
4
6-6-7
SCR reversing valve; short circuit to ground
1505
524057
2
Electric fuel pump; fuel pressure build up error