JLG 4017PS Service Manual User Manual
Page 261

9-103
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
Electrical System
1431
524028
2
8-1-5
CAN message PROEGRActr; plausibility error
1432
524029
2
8-1-5
Time out Error of CAN-Receive-Frame ComEGRActr -
exhaust gas recirculation positioner
1436
524034
5
8-1-6
Disc Separator; open load
1437
524034
12
8-1-6
Disc Separator; powerstage over temperature
1438
524034
3
8-1-6
Disc separator; short circuit to battery
1439
524034
4
8-1-6
Disc separator; short circuit to ground
1440
524030
7
EGR actuator; internal error
1441
524031
13
EGR actuator; calibration error
1443
524033
7
EGR actuator; due to overload in Save Mode
1444
2621
5
Flush valve burner (EPV DPF-System); open load
1445
2621
12
Flush valve burner (EPV DPF-System);
powerstage over temperature
1446
2621
3
Flush valve burner (EPV DPF-System); short circuit to battery
1447
2621
4
Flush valve burner (EPV DPF-System); short circuit to ground
1448
175
0
1-4-4
High customer oil temperature; warning threshold exceeded
1449
175
0
1-4-4
High customer oil temperature; shut off threshold exceeded
1455
3711
12
Regeneration temperature (PF lt Rgn Light Off) not reached;
regeneration aborted
1457
524055
4
Spark Plug Control Unit (SPCU); short circuit to ground
1458
523960
0
7-7-1
High exhaust gas temperature EGR; warning threshold exceeded
1459
523960
1
7-7-1
High exhaust gas temperature EGR; shut off threshold exceeded
1460
1180
0
8-1-4
Exhaust gas temperature upstream turbine;
warning threshold exceeded
1461
1180
1
8-1-4
Exhaust gas temperature upstream turbine; shut off threshold
exceeded
1462
1180
0
5-5-6
Exhaust gas temperature upstream turbine;
warning threshold exceeded
1463
1180
1
5-5-6
Exhaust gas temperature upstream turbine; shut off threshold
exceeded
1474
524037
5
Ashlamp; open load
1475
84
2
5-2-1
Sensor vehicle speed; plausibility error
1477
524037
3
Ashlamp; short circuit to battery